El anwar A, El behery M, Nouh A, Seliem B. Does Uterine Artery Doppler or Copper Intrauterine Device Location by Three Dimensional Transvaginal Ultrasound Correlates with Clinical Symptoms?. WebmedCentral OBSTETRICS AND GYNAECOLOGY 2010;1(9):WMC00702
doi: 10.9754/journal.wmc.2010.00702
No
Submitted on: 22 Sep 2010 05:54:09 PM GMT
Published on: 22 Sep 2010 07:21:44 PM GMT

Abstract


Aim of study: To evaluate the effectiveness of using uterine artery color Doppler and location of intrauterine copper device by three dimensional transvaginal ultrasound in relation to abnormal vaginal bleeding and pain.
Methods: Three dimensional transvaginal ultrasound examinations were carried out to 180 women 3-6 months after IUD insertion. Seventy six women were suffering from pain (groupI), forty four presenting with abnormal vaginal bleeding (group II), and sixty women with no complaint (group III). The distance between top of the IUD and inner endometrium E-IUD, IUD and fundus F-IUD and ends of IUD to sidewall of uterus S-IUD were measured. Uterine artery pulsitilty index was measured by color Doppler for all women.
Results: No statistical significant differences between the three groups regarding E-IUD, F-IUD and S-IUD. Mean uterine artery pulsitility index was significantly lower in women suffering from pain with IUD than women with excess menses; and both had lower mean pulsitility index than control group (1.1±1.0, 1.8±0.41, 2.4 ±0.8 respectively, P
Conclusion: Location of IUD using 3D transvaginal ultrasound did not differ between IUD complaining and non complaining women, however uterine artery pulsitility index is lower in women suffering from bleeding or pain with IUD.

Introduction


Intrauterine devices (IUD) is one of the most effective contraceptive methods due to its simplicity, reversibility and practicability; copper IUDs failure rate is, 0.8% for the first insertion year, and also for a 10-year period (1). The copper IUD is more effective than inert IUDs, because of safety, contraceptive action and decreasing risk of pelvic inflammatory disease. The most common copper (IUD)-related side effects are uterine bleeding and/or menstrual pain. and these side effects often directly affect compliance with, and, consequently, the continuation rates of the method (2,3).

It has been suggested that IUD-related side-effects, such as secondary dysmenorrhoea and metrorrhagia, may be caused by an increased prostaglandin synthesis in the endometrium that could lead to changes in endometrial blood flow and capillary permeability and such changes may cause menorrhagia.(3,4).Generally, it is thought that bleeding, or dysmenorrhea induced by an IUD may be secondary to a decrease in uterine arterial resistance and an increase in uterine blood flow, which are both detectable by color Doppler sonography(5,6).

Routine follow up of asymptomatic women with IUDs ,and evaluation ofsymptomatic patients include transvaginal ultrasonography to rule out IUD malposition and other complications are recommended(7).

Because failed contraceptive action of the IUD may be secondary to device malpostion, a sonographic survey can identify displaced devices. However, because the frontal view of the IUD may be impossible to visualize by two-dimensional ultrasound ,evaluation of the two arms of the device can be very difficult ,and 2 D sonography may fail in the detection of misplacement of the IUD in about 9% of cases (8).

The use of 3Ds Ultrasound in studying IUD allowed complete simultaneous imaging of all parts of the IUD. In three plane mode, all parts of the IUD could be visualized after volume rendering (8).

The objective of this study was to evaluate the effectivness  of using uterine artery Doppler and IUD location by three dimensional transvaginal ultrasound in relation to IUD side effects.

Methods


Between May 2007 and November 2009 women attending the family planning clinic of Obstetrics and Gynecology Department, Zagzig University for IUD insertion were enrolled in this prospective study. Exclusion criteria were patients with irregular menstrual cycles, bleeding diathesis, pregnancy, acute or chronic pelvic inflammatory disease, cervicitis, benign or malignant gynecologic tumors, congenital uterine anomalies. The study was approved by the local hospital ethics committee and an informed consent was obtained from all participants.

Transvaginal ultrasonographic examination was performed to ascertain uterine position and to  exclude any contraindication prior to IUD insertion. Patients were advised to attend the family planning clinic 3–6 months after IUD insertion on the 3rd or 4th day of the menstrual cycle. During The second follow up visit, three dimentional TVS examinations were done using ( GE, Healthcare, Voulson 730 PRO V) medical system equipped with (6-9 MHz) transvaginal probe. Women's satisfaction with  IUD were the basis for categorizing them into three groups: Seventy six women were suffering from pain(groupI), forty four presenting with excess vaginal bleeding were(group II), and sixty non complainin women were taken as a control group (group III). Two trained Ob/Gyn consultant blinded to patients complaint performed the ultrasound examinations. The uterus was displayed in three orthogonal planes. Volume rendering was used in order to visualize the arms of the IUD in y-axis.

To identify the position of the uterus sonographically three measurements are taken, The distance from upper end of the IUD to the inner surface of the endometruim IUD-E. The distance of upper end of IUD to the peritoneal surface of uterine fundus IUD-F, and the distance between mean ends of T IUD and side wall of uterus IUD-S.

The color guided pulsed wave Doppler signals were obtained at the site of visualization of the uterine artery near its origin from the iliac artery. The angle of insonation was kept less than 30?, Doppler parameters(pulsaitility index) was calculated with machine software whenever at least three similar sequential waveforms.

Statistical analysis was performed using One way ANOVA  for comparing groups of study in addition to ROC curve for tests of sensitivity, specificity

Discussion


In this study, We choose 3D ultrasound because the 2D ultrasound is limited to transverse views of the shaft and the arms or other smaller parts of the IUD and ,as a result ,it cannot be investigated completely. This runs in agreement of Lee et al who mentioned that 3DUS enables imaging of the entire IUD (the shaft and the arms)(8). Furthermore Bonilla-Musoles compared 2D with 3D ultrasound regarding identification and location of IUDs in 66 asymptomatic women. The IUD was misidentified in eight cases (12.2%) with 2D-TVU ,and  it was failed to identify the position of the device In six cases (9.1%). Whereas, all IUDs were identified and located accurately with 3D-TVU (9).

Most bleeding and pain side effects were found to decrease over time as the T shaped IUD accommodate its position in the uterine cavity during the first 3 months following insertion(10). For this reasons we choose to evaluate three to six months after insertion. In a study by Petta et al trans abdominal and /or trans vaginal 2D ultrasound were performed to compare 155 patients presenting with complains related to IUD use with 56 without complains. About 50% of complainers had top-fundal distance more than 4 mm, compared to 28% of non complainers. An inter cornual diameter, too small (less than 30 mm) or too wide (greater than or equal to 38 mm), was significantly more frequent in women complaining of bleeding and pain (13).

On the other hand, an earlier cross sectional study had shown a total lack of association between 2D sono graphically determined IUD position and complains of bleeding and pain (11) and found that  that IUD may be unnecessary removed as they were  incorrectly displaced as determined by ultrasound.

In contrast, other researchers found that sonography is important in assessing the complications of IUDs including a low position, associated infection, myometrial migration, uterine perforation, associated intrauterine or extrauterine pregnancy   and retention of fragmentation of IUD, and considered trans vaginal ultrasound to be  the best technique to determine the intrauterine location of IUDs (14).It is even better than hysteroscopy and thread length. Moreover, some studies have suggested some association between displacement of the IUD and failure of contraception, tubal pregnancy, abdominal pain metrorrhagia and higher rate of expulsion (13,14)

In this cross sectional study, sixty non complaining women were compared to one hundred twenty women complaining from IUD side effects. No differences regarding body mass index, parity and mode of last delivery were found. Using 3D ultrasound, we found E-IUD, and F-IUD in S-IUD  Did not differe significantly among any of the groups. A similar study by Hösli et al to estimate the distance measurement between copper IUD and myometrium or endometrium with 2D and 3D did not differ significantly in complaining and non complaining women  (19.54mm±6.13 vs. 19.48±6.39, 5.58±4.57 vs. 5.21±4.57).

We found a significant increase in uterine artery blood flow in patients who presented with copper IUD side effects reflected as decreased  uterine artery pulsatility index with a statistically significant difference between the control group(PI=2.6±0.8, group II (bleeding induced IUD ,PI=1.8±0.41 ) and group III (pain induced IUD,PI 1.1±1.0).  Our results runs in agreement with Frajndlich et al(16) who Conducted a study on 68 women, 44 were using intrauterine contraceptive device and 24 women not using any method of contraception, uterine artery Doppler PI was significantly lower in women with IUD induced bleeding than those without abnormal vaginal bleeding or in women not using any method of contraception. The author concluded that  patients with uterine artery pulsatility index less than 2 had a higher risk for development of intrauterine contraceptive device –induced bleeding ( 16,17).

Souza and Geber(18) compared uterine artery pusitility index before and after IUD insertion., and found  that the presence of an IUD does not interfere with the vascular flow of the uterine arteries as shown by Doppler flow assessments 1 month after insertion.

In this study when we used 1.5 as a cut –off value for uterine artery pulsitility index after Cu T IUD insertion: the sensitivity ,and specificity were 81.7%,and 69.2%, respectivly for the prediction of abnormal bleeding and pain with copper T IUD.

In conclusion Location of IUD using 3D transvaginal ultrasound did not differ between IUD complaining and non complaining women, however uterine artery pulsitility index is lower in women suffering from bleeding or pain with IUD.

References


1. Mestad RE, Kenerson J, Peipert JF. Reversible contraception update: the importance of long -acting reversible contraception. Postgrad Med. 2009;121(4):18-25.
2. Ruddick C. Long-acting reversible contraception: reducing unintended pregnancies. Community Pract. 2009 ;82(9):24-7.
3. Yigit N, , Kacar M, Yigit H, Kosar P, Kosar U.The effects of copper contraceptive intrauterine device on the uterine blood flow: A prospective transvaginal Doppler study. .J of Clinic Ultrasound 2009 37 (7):380 – 4
4. Frajndlich R, Corleta HE, Frantz N. Color Doppler sonographic study of the uterine artery in patients using intrauterine contraceptive devices. J Ultrasound Med 2000;19:577-9
5. Frajndlich R, Corleta HE, Frantz N. Color Doppler sonographic study of the uterine artery in patients using intrauterine contraceptive devices. J Ultrasound Med 2000;19:577.
6. Jarvela I, Tekay A, Jouppila P. The effects of a copper- intrauterine device on the uterine artery blood flow in regularly menstruating women. Human Reprod 1998;13:1841.
7.Vasky DV, Cohen SM, Hochner-Celnikier D , Lev-Sagie A, Yagel M, Xu K,Luo Q. The use of three –dimentional ultrasound imaging in detecting the type and location of intrauterine contraceptive device .Zhonghua Yi Xa Zhi 2002;10;82(7):459-61
8. Lee A, Eppel W, Sam C ,Kratochwil A, Deutinger J ,Bernaschek G.Intrauterine device localization by three-dimentional transvaginal sonography. Ultrasound Obstet Gynecol. 1997;10(4): 289-92
9. Bonilla-Musoles F ,Raga F ,Osborne NG, Blanes J . Control of intrauterine device insertion with three dimentional ultrasound : Is it the future ?J Clin Ultrasound 1996;24(5):263-7
10. Hubacher D, Chen P, and Park S. Side effects from the copper IUD:do they decrease over time ? Contraception 2008; 79(5):356-62
11. FaÚndes D, Perdigão A, FaÚndes D, Bahamondes L and Petta C A .T-shaped IUDs accommodate in their position during the first 3 months after insertion.Contraception 2000 ;62,165-8
12. Peri N, Graham D, Levine D. Imaging of intrauterine contraceptive devices. J Ultrasound Med 2007; 26(10):1389-401
13. Petta CA, FaÚndes D, Pimentel E, Dias J and Bahamondes . The use of vaginal ultrasound to identify copper T IUDs at high risk of expulsion .Contraception 1996:54(5) :287-9
14. FaÚndes D., Bahamondes L., FaÚndes,A., Petta C A,Diaz , J and Marchi V. No relation between the IUD position evaluated by ultrasound and complains of bleeding and pain.Contraception 1997;56:43-7
15. Petta CA, FaÚndes D, Pimentel E, Dias J and Bahamondes . The use of vaginal ultrasound to identify copper T IUDs at high risk of expulsion .Contraception 1996 :54(5) :287-9
16. Anteby E, Revel A, Ben-Chetrit A, Rosen B, Tadmor O, and Yagel S. Intrauterine device failure:relation to its location within the uterine cavity .Obstet Gynecol 1993; 81:112-4
17. Frajndlich R,von Eye Corleta H,Franz N. Color Doppler sonographic study of the uterine artery in patients using intrauterine contraceptive device.J Ultrasound Med 2000;19:577-9
18. Momtaz M, Zayed M, Rashed K, Idriss O. Doppler study of the uterine artery in patients using an intrauterine contraceptive device .Ultrasound in obstet and Gynecol 2003 ;4(3) :231-4
19. Souza MA, Geber S. Doppler color flow analysis of the uterine arteries before and after intrauterine device insertion: a prospective study. J Ultrasound Med. 2006 ;25(2):153-7.

Source(s) of Funding


None

Competing Interests


No conflicit of interest

Disclaimer


This article has been downloaded from WebmedCentral. With our unique author driven post publication peer review, contents posted on this web portal do not undergo any prepublication peer or editorial review. It is completely the responsibility of the authors to ensure not only scientific and ethical standards of the manuscript but also its grammatical accuracy. Authors must ensure that they obtain all the necessary permissions before submitting any information that requires obtaining a consent or approval from a third party. Authors should also ensure not to submit any information which they do not have the copyright of or of which they have transferred the copyrights to a third party.
Contents on WebmedCentral are purely for biomedical researchers and scientists. They are not meant to cater to the needs of an individual patient. The web portal or any content(s) therein is neither designed to support, nor replace, the relationship that exists between a patient/site visitor and his/her physician. Your use of the WebmedCentral site and its contents is entirely at your own risk. We do not take any responsibility for any harm that you may suffer or inflict on a third person by following the contents of this website.

Comments
0 comments posted so far

Please use this functionality to flag objectionable, inappropriate, inaccurate, and offensive content to WebmedCentral Team and the authors.

 

Author Comments
0 comments posted so far

 

What is article Popularity?

Article popularity is calculated by considering the scores: age of the article
Popularity = (P - 1) / (T + 2)^1.5
Where
P : points is the sum of individual scores, which includes article Views, Downloads, Reviews, Comments and their weightage

Scores   Weightage
Views Points X 1
Download Points X 2
Comment Points X 5
Review Points X 10
Points= sum(Views Points + Download Points + Comment Points + Review Points)
T : time since submission in hours.
P is subtracted by 1 to negate submitter's vote.
Age factor is (time since submission in hours plus two) to the power of 1.5.factor.

How Article Quality Works?

For each article Authors/Readers, Reviewers and WMC Editors can review/rate the articles. These ratings are used to determine Feedback Scores.

In most cases, article receive ratings in the range of 0 to 10. We calculate average of all the ratings and consider it as article quality.

Quality=Average(Authors/Readers Ratings + Reviewers Ratings + WMC Editor Ratings)