ORTHODONTICS

Herbst, class II malocclusion, fixed appliance, functional appliance

Favale M, Di Luzio C, Caputo M, Bellisario A, Squillace F. The effectiveness of Herbst appliance in II class malocclusion. WebmedCentral ORTHODONTICS 2017;8(11):WMC005368

This is an open-access article distributed under the terms of the Creative Commons Attribution License(CC-BY), which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
No
Submitted on: 07 Nov 2017 05:41:43 PM GMT
Published on: 08 Nov 2017 05:44:03 AM GMT

Abstract


The aim of this review is to evaluate the effectiveness of using Herbst Appliance in II class malocclusion caused by a backward mandibular position. Herbst has an high clinical success rate, indeed it is one of the most used devices.

Materials and method: For this review scientific articles found in data base like PubMed, EMBASE, Cochrane Library and web of Science have been taken into account.

Discussion: Interesting results have been obtained by analyzing several studies. A significant decrease has been measured in SNA and ANB, due to an increase of SNB. It is induced by Herbst device which pushed forward and cause the growth of the jaw.

Futhermore Co-Gn have been increased following Herbst treatments, indicative of anteriorly positioned mandibular base and increased mandibular length. This may suggest that the sagittal changes of mandibular are brought about changes in both condylar positions and mandibular lengths.

Conclusions: Herbst appliance is an efficacious system to treat II class, thanks to the induced skeletal and dento-alveolar modifications.

Introduction


Second class malocclusion is one of the most common skeletal alterations, that affects the Caucasian population in a percentage from 12% up to 32% [1]. The diagnosis of II class is possible by performing the cephalometric analysis of x-ray in lateral view and by a clinical aesthetic examination. Taking into account the lateral radiograph, analyzing the SNA and SNB in important to assess if the second class is caused by the mandibular reduction in length or maxillary excess, or a mix of both; If the value of ANB is greater than 4 degrees, a II class is detected. The Witts index is another parameter useful to value the typology of class and the divergency: it consist of a linear measurement of the Ao - Bo segment, where Ao and Bo represent respectively the projection of point A and point B on the occlusal plane.

Furthermore, it is important to consider the inclination of the incisors and the divergence of patient.

We could classify II class malocclusion in three different types: skeletal, dento-alveolar and the pure dental type. These alterations require dental or skeletal approaches depending of malocclusion nature [3]. If the type of II class is skeletal type, It could be treated with functional or mechanical orthopedic appliances.

Herbst appliance is one of many functional devices used to treat II class malocclusion. It was developed by Emil Herbst in the early 1900s and it was reintroduced by Pancherz in the late 1970 [2].

One of major advantages of Herbst is that it does not require the patient to cooperate and this the reason of it hight success rate. Therefore it results to be one of the most used appliance for II class treatment [7].

Herbst appliance has bilateral telescope anchored to lower and upper arch and so it keeps mandible in protrusion 24h/die. This allows the aesthetic profile to improve immediately.

On the other hand, many complications are relared to the device during the treatment period: lower splint breakage, band or component fracture or debonding, screw loosening, rod distortion, pivot breakage, and soft tissue injuries [6].

The mucous injury rate is about 12% [8], this is a moderate-low incidence with respect to other functional appliances, but it is an important aspect of Herbst complications.

Elevate incidence of appliance fracture has lead to develop different type of design.

Pancher used a Herbst device made of an outer cylinder and an inner tube that ended with two eyelets. The tube was anchored to the upper first molar band and to the band of the lower first premolar using two screws for eyelets and screwed into two nuts welded to the respective bands.

Other types of older design were the Herbst appliance with stainless steel crowns on the maxillary first molars and removable mandibular acrylic splint or the Herbst appliance with four stainless steel crowns on the first upper and lower molars.

At the beginning of the 2000s, a new Herbst was introduced into the market, consisting of a new type of band (Rollo band) and a telescopic Herbst. The Rollo band is similar to a preformed crown. It has a hole in the chewing part that permits the correct cure of the cement and facilitates removal. The Rollo band is thicker than a traditional band (the metal thickness is .007 mm) to increase load resistance and sand blasting improves retention.

There are three types of telescopic Herbst:

I. Herbst Miniscope

II. Herbst HTH

III. Herbst MTH

They have common design, consisting of two cylinders and one piston running inside. Both the inner cylinder and the piston have a stop on the distal terminal used to avoid disassembly. The use of the Rollo bands and these types of telescopic systems have reduced the frequency of decay and fracture of the device.

Herbst miniscope guarantees 6 degrees of lateral movements, while the Herbst HTH allow 20 degrees of movements and the Herbst MTH makes side movements possible up to about 13 degrees. The Herbst MTH is the type that has lower amount of appliance fractures due to lateral movement. The facilitation of clinical management by the orthodontists has been accompanied by a decrease in comfort for the patient. Infact using Herbst Miniscope and Herbst HTH an increase in the number of decubitus ulcers has been obtained. Herbst MTH was created to overcome the problem of decubitus ulcers that could occur with the other two models. The ulcers are caused by excessive latency: when the jaw moves on one side, the outer cylinder of the hinge protrudes excessively into the interior of the vestibule on the outer side of the vestibule and this causes an excessive pressure on genital mucosa. The problem occurs mainly at night in patients who tends to sleeping on side.

The Herbst determines dental effects like the distalisation (up to 2.8mm) and upper molar intrusion, the retro-inclination (up to 3.5mm) and upper incisor extrusion, the mesialization (up to 1.8mm) and extrusion lower molars, buccal (up to 10.5mm) and intrusion of the lower incisors [11].

The skeletal effects are the reduction of the maxillary growth (headgear effect), increasing in growth of mandible, the renew of the articular fossa [12], a slight clockwise rotation of the occlusal plane. The inferior jaw can also growth till 4 mm, but is necessary a rotation of Pogonion for an anterior positioning in a sagittal view is necessaries.

Materials and method


Several articles have been published about the use of the Herbst device in the second classes. For this work it is been taken in account articles in literature published in data-base such as PubMed, EMBASE, Cochrane Library and Web of Science.

The keywords used were: Herbst, Class II Malocclusion and Orthodontic Functional Appliances.

No restrictions of languages have been fixed; articles until February 2017 have been taken into account, items that were not considered eligible were analyzed and then removed. As results of these analysis only 20 full articles have been selected.

Review


Many studies demonstrate the effectiveness of the Herbst device. It is indeed, one of the most used devices to treat second class due to mandibular backward position.

The speed and effectiveness of the treatment may lead the clinician to prefer it to other mobile functional devices, anyway it is very important to select the patient.

The fixed equipment requires a low collaboration, which is in contrast with the high collaboration that the patient regarding oral hygiene requires. Indeed fixed device could easily lead to an increase of the risk of plaque level and consequently to an increase of the risk of demineralization; for this reason it is important to instruct the patient to cure his/her oral hygiene.

Treatment time using Herbst appliance is about of 9 months [13-14]. The variables depends only to the individual response to the treatment: skeletal age (further away from the growth spurt and greater the dento-alveolar effects and minor skeletal ones) and the genetic pattern of the patient mandibular growth [15-5]. In adults the treatment lasts longer than 12 months, because the patient has an adult bone structure and a dental alveolar already structured.

According to Panchez et al [16]changes occurring in second-class patients after therapy with Herbst are the following ones: correction of occlusal ratio in class I with an average molar advancement of 6.1 mm (due to 37% to a skeletal response), overjet correction of about 8.4 millimeters due to skeletal modification in 27% of cases and upper and lower anterior teeth inclined.

Class II patients treated with the Herbst appliance show changes of TMJ with anterior displacement of the condyles and remodeling glenoid fossae [18]; this is one reason of moving forward of the jaw.

Furthermore Pancherz noticed in the long-term studies that Herbst's device often led to the recurrence in the immediate post-treatment. For this reason, he recommend to use it in premature permanent dentition to limit changes only to the mandibular protrusion [21].

It is possible to use the Herbst device in association with the temporary anchorage devices (TADs)[22] to increase the anchorage, contain dental effects (in order to reduce undesirable proclination of lower incisors) and enhance the skeletal response.

Discussion


Thanks to the new types of Herbs this device fits strongly the second class therapy. Its effects are similar to the ones generated by the Twin Block functional device.

Xin Yang, in a meta-analysis [19], analyzes SNA, SNB, ANB, mandibular plane angle, Co-Go, Co-Gn, overjet, overbite and molar relationship modification. He found a significant decrease in SNA and ANB due to an increase of SNB that Herbst appliance has induced with the forward position and growth of mandible. Furthermore, Co-Gn have been increased following Herbst treatments, indicative of anteriorly positioned mandibular base and increased mandibular length; this may suggest that the sagittal changes of mandibular are brought about by changes in both condylar positions and mandibular lengths.

Several studies show that Herbst appliance reduce dental overjet, dental overbite and molar discrepancies. As mentioned above, this appliance could forward mandibles, and this is a contribute to the improvement of dental discrepancies.

The recurrence is more pronounced for dental effects than skeletal [20], the ideal age of treatment is close to pubertal growth spurt, in early permanent dentition.

However, also adult patients are affected by dental effects and the slight remodeling of the glenoid fossae with an anterior displacement of condyle, although the treatment is a bit longer and less effective compared to patient in growth. Anyway, in adult and young patients it is recommended to avoid recurrences.

Conclusion


Several studies selected showed the effectiveness of use Herbst appliance in II class.

Among the major effects we could find:

  • an increased anteroposterior length of the mandible;
  • increased vertical height of the ramus;
  • increase in lower facial height;
  • mandibular incisors proclination;
  • mesial movement of lower molars;
  • distal movement of upper molars.

There are also effects in the TMJ like a remodeling of glenoid fossae and anterior displacement of condyle.

The fracture of the device and the mucous membrane decubitus remain among the major side effects of this device. Indesiderable dento-alveolar effect could be contained by the use of mini screw.

References


  1. Bazant, V. and Miksa, J. (1960) Die Hau gkeit der Okklusionsanomalien in sagittaler Richtung in der Klassi kation nach Angle bei Erwachsenen. Fortschritte der Kieferorthopadie, 21, 328-338;
  2. Pancherz, H. (1979) Treatment of class II malocclusions by jumping the bite with the Herbst appliance. A cephalometric investigation. American Journal of Orthodontics, 76, 423-442;
  3. Keim RG, Berkman C. Intra-arch maxillary molar distalization appliances for Class II correction. J Clin Orthod 2004;38:505-11;
  4. VanLaecken R, Martin CA, Dischinger T, Razmus T, Ngan P. Treatment effects of the edgewise Herbst appliance: a cephalometric and tomographic investigation. Am J Orthod Dentofacial Orthop. 2006;130:582-593;
  5. Pancherz H, Bjerklin K, Hashemi K. Late adult skeletofacial growth after adolescent Herbst therapy: a 32-year longitudi- nal follow-up study. Am J Orthod Dentofacial Orthop. 2015;147:19-28;
  6. Moro A, Janson G, Moresca R, Freitas MR de, Henriques JFC. Comparative study of complications during Herbst treatment with Cantilever Bite Jumper and removable mandibular acrylic splint. Dental Press J Orthod. 2011;16: e1-e10;
  7. Keim RG, Gottlieb EL, Nelson AH, Vogels DS. 2002 JCO study of orthodontic diagnosis and treatment procedures: part 1, results and trends. J Clin Orthod. 2008;42:625-640;
  8. O Brien e coll.: Effectiveness of treatment for class II malocclusion whith the Herbst or Twin Block appliances: a randomized, controlled trial. Am J Orthod 2003;124: 128-137;
  9. Schioth T, Bremen JV, Pancherz H, Ruf S. Complications during Herbst appliance treatment with reduced mandibular cast splints. J Orofac Orthop. 2007;68:321-327;
  10. Moro A, Janson G, Moresca R, Freitas MR de, Henriques JFC. Comparative study of complications during Herbst treatment with Cantilever Bite Jumper and removable mandibular acrylic splint. Dental Press J Orthod. 2011 ;16: e1-e10;
  11. Wieslander L.: Intensive treatment of severe Class II malocclusions with a headgear-Herbst appliance in the early mixed dentition. Am J Or- thod. 1984; vol 86(1):1-13Wieslander, L.: Long-term effect of treatment with the headgear-Herbst appliance in the early mixed dentition. Stability or relapse ? Am J Or- thod 1993; vol 104: 319-329;
  12. Pancherz H., Ruf S., Kohlnas P.:Effective condylar growth” and chin position changes in Herbst treatment: a cephalometric roentgeno- graphic long-term study. Am J Orthod 1998; vol 114: 437-446
  13. Clark W. J:Tecnica Funzionale con Twin Blocks Edizione Masson;
  14. Pancherz H., Hägg U.: Dentofacial orthopedics in relation to somatic maturation. Am J Orthod 1985; vol 88 (4): 273-287;
  15. Ruf, S.; Pancherz, H.: Orthognatic surgery dentofacial orthopedics in adult Class II Division I treatment: Mandibular sagittal split osteotomy versus Herbst appliance. Am. J. Orthod Dento- fac Orthop 126:140-152, 2004;
  16. The mechanism of Class II correction in late Herbst treatment. Konik M, Pancherz H, Hansen K. Am J Orthod Dentofacial Orthop. 1997 Jul;112(1):87-91;
  17. OGEDA,Paulo Cezar Rodrigues and ABRAO, Jorge. Assessment of the displacement of the upper molars using the Herbst appliance; Rev. Dent. Press Ortodon. Ortop. Facial. 2004, vol.9, n.4, pp. 31-43. ISSN 1415-5419;
  18. "Three-dimensional treatment outcomes in Class II patients treated with the Herbst appliance: A pilot study"; Megan LeCornu , Lucia H.S. Cevidanes , Hongtu Zhu , Chih-Da Wu , Brent Larson , Tung Nguyen; American Journal of Orthodontics & Dentofacial Orthopedics Volume 144, Issue 6 , Pages 818-830, December 2013;
  19. Xin Yang, Yafen Zhu, Hu Long, Yang Zhou, Fan Jian, Niansong Ye, Meiya Gao and Wenli Lai.The effectiveness of the Herbst appliance for patients with Class II malocclusion:a meta-analysis.European Journal of Orthodontics 2016. 324-333 doi:10.1093/ejo/cjv057 Advance Access publication 25 August 2015;
  20. Ruf S., Pancherz H.: The effect of Herbst appliance treatment on the mandibular plane angle: a cephalometric roentgenographic study. Am J Orthod 1996;
  21. Profitt W.R., Henry W. Fields, Jr DAvid M. Saver. Contemporary Orthodontics third edition
  22. Cesare Luzi, Valeriano Luzi, Birte Melsen. Mini-implants and the efficiency of Herbst treatment: a preliminary study; Progress in Orthodontics 2013, 14:21, doi:10.1186/2196-1042-14-21
  23. Chen, J. Y. , L. A. Will , and R. Niederman . "Analysis of efficacy of functional appliances on mandibular growth". Am J Orthod Dentofacial Orthop 2002. 122:470-476.
  24. Carlos Flores-Mir, Abenaa Ayeh, Ashim Goswani, Shouresh Charkhandeh. Skeletal and Dental Changes in Class II division 1 Malocclusions Treated with Splint-Type Herbst Appliances. The Angle Orthodontist Volume 77, Issue 2 (March 2007);
  25. Sabine Ruf, Hans Pancherz; Temporomandibular joint growth adaptation in Herbst treatment: a prospective magnetic resonance imaging and cephalometric roentgenographic study. European Journal of Orthodontics 20 (1998) 375-388

Source(s) of Funding


No funds has been taken

Competing Interests


None

Reviews
0 reviews posted so far

Comments
0 comments posted so far

Please use this functionality to flag objectionable, inappropriate, inaccurate, and offensive content to WebmedCentral Team and the authors.

 

Author Comments
0 comments posted so far

 

What is article Popularity?

Article popularity is calculated by considering the scores: age of the article
Popularity = (P - 1) / (T + 2)^1.5
Where
P : points is the sum of individual scores, which includes article Views, Downloads, Reviews, Comments and their weightage

Scores   Weightage
Views Points X 1
Download Points X 2
Comment Points X 5
Review Points X 10
Points= sum(Views Points + Download Points + Comment Points + Review Points)
T : time since submission in hours.
P is subtracted by 1 to negate submitter's vote.
Age factor is (time since submission in hours plus two) to the power of 1.5.factor.

How Article Quality Works?

For each article Authors/Readers, Reviewers and WMC Editors can review/rate the articles. These ratings are used to determine Feedback Scores.

In most cases, article receive ratings in the range of 0 to 10. We calculate average of all the ratings and consider it as article quality.

Quality=Average(Authors/Readers Ratings + Reviewers Ratings + WMC Editor Ratings)