Review articles
 

By Dr. Juergen R Roemisch , Dr. Waltraud Kaar , Dr. Alfred Zoechling , Dr. Christoph Kannicht , Mrs. Marietta Putz , Dr. Guido Kohla , Dr. Petra Schulz , Dr. Katharina Pock , Dr. Susanna Huber , Dr. Birte Fuchs , Dr. Andrea Buchacher , Mrs. Dagmar Krause , Dr. Josef Weinberger , Dr. Gerold Rempeters
Corresponding Author Dr. Juergen R Roemisch
Research & Development Octapharma PPGmbH, - Austria 1100
Submitting Author Dr. Juergen R Roemisch
Other Authors Dr. Waltraud Kaar
Octapharma PPGmbH, Research and Development, Oberlaaerstrasse 235nVienna - Austria 1100

Dr. Alfred Zoechling
Octapharma PPGmbH, Research and Development, Oberlaaer Strasse 235nVienna - Austria 1100

Dr. Christoph Kannicht
Octapharma PPGmbH, Molecular Biochemistry, Arnimallee 22nBerlin - Germany 14195

Mrs. Marietta Putz
Octapharma PPGmbH, International Marketing Access, Oberlaaer Strasse 235, Vienna - Austria 1100

Dr. Guido Kohla
Octapharma PPGmbH, Molecular Biochemistry, Arnimallee 235, Berlin - Germany 14195

Dr. Petra Schulz
Octapharma PPGmbH, Research and Development, Oberlaaer Strasse 235nVienna - Austria 1100

Dr. Katharina Pock
Octapharma PPGmbH, Research and Development, Oberlaaer Strasse 235nVienna - Austria 1100

Dr. Susanna Huber
Octapharma PPGmbH, Research and Development, Oberlaaer Strasse 235nVienna - Austria 1100

Dr. Birte Fuchs
Octapharma PPGmbH, Molecular Biochemistry, Arnimallee 22nBerlin - Germany 14195

Dr. Andrea Buchacher
Octapharma PPGmbH, Quality Control, Oberlaaer Strasse 235nVienna - Austria 1100

Mrs. Dagmar Krause
Octapharma PPGmbH, QC Methodology, Oberlaaer Strasse 235nVienna - Austria 1100

Dr. Josef Weinberger
Octapharma PPGmbH, QC Management, Oberlaaer Strasse 235nVienna - Austria 1100

Dr. Gerold Rempeters
Octapharma OPG-D, General Manager, Wolfgang-Marguerr-Allee 1nSpringe - Germany 31832

IMMUNOTHERAPY

IVIG, Thromboembolic Event, Activated Factor XI, Thrombin Generation Assay, TGA, Peak Thrombin Concentration, PTC, FXI Adsorption

Roemisch JR, Kaar W, Zoechling A, Kannicht C, Putz M, Kohla G, et al. Identification of Activated FXI as the Major Biochemical Root Cause in IVIG Batches Associated with Thromboembolic Events. Analytical and Experimental Approaches Resulting in Corrective and Preventive Measures Implemented into the Octagam® Manufacturing Process. WebmedCentral IMMUNOTHERAPY 2011;2(6):WMC002002
doi: 10.9754/journal.wmc.2011.002002
No
Submitted on: 22 Jun 2011 01:13:48 PM GMT
Published on: 23 Jun 2011 06:19:40 PM GMT

Abstract


During the year 2010 a surprising increase of thromboembolic events (TEEs) was observed after administration of distinct Octagam® 5% (human normal immunoglobulin 50 mg/ml) batches to patients. Immediately, Octapharma initiated a massive voluntary recall of Octagam batches from EU and US markets in August 2010. In Europe, the marketing authorization was suspended in September 2010. In order to identify the biochemical root cause(s) of the TEEs in concerned Octagam batches, suitable assays had to be evaluated. In particular, a Thrombin Generation Assay (TGA) turned out to be the most sensitive and predictive test-system to assess an increased procoagulant potential. A number of experiments and analyses, including thrombelastometry, an activated Factor XI (FXIa) assay as well as all coagulation system and contact phase related assays identified FXIa as the major procoagulant activity. Other procoagulant compounds were excluded. Only moderate Kallikrein activities were found in distinct Octagam batches, which had a negligible contribution to thrombin generation. The Wessler stasis model in rabbits confirmed the biochemical results and finally provided the in vivo proof of the successful removal of FXI(a) by implementation of corrective and preventive measures into the manufacturing process. FXI minimization is now controlled by in-process sample testing. In addition, TGA was validated and implemented for routine Octagam batch release. Consequently, based on the elucidated biochemical and technical root causes and corresponding implemented measures, the CHMP recommended the lifting of the suspension of the marketing authorization in Europe in April 2011, with confirmation following by the EMA in May 2011. A corresponding file is currently under review by the FDA.

Introduction


Octagam®5% has been in use for more than 17 years with an excellent efficacy and tolerability and an overall adverse event rate of less than 0.35% in 10 years (1,2). However, during the year 2010 a surprising increase in thromboembolic events (TEEs) was observed after administration of distinct Octagam®5% batches to patients (3). The predisposition of patients with underlying diseases and thrombotic risk factors had to be taken into consideration, which meant that only a limited number of patients developed TEEs per Octagam batch. A massive voluntary recall of Octagam batches was initiated by Octapharma in August 2010. At the same time the biochemical root cause analysis of these batches had started (4). The lifting of the suspension of the MA in Europe from September 2010 was recommended by the CHMP in April 2011 (5). A corresponding file is currently under review by the FDA.
This decision was taken after Octapharma had identified the biochemical and technical root causes. Corrective and preventive measures were implemented into the manufacturing process including sensitive assays for in-process and final product testing, the latter as an additional validated routine Quality Control release test.
In order to facilitate the efficient, robust and consistent minimization of the procoagulant potential in the final product, test-systems had to be explored, which were suitable and sufficiently sensitive to support the elucidation and correction of the technical root during the manufacturing process. Global coagulation assays such as PT or APTT did not show a sufficiently sensitive performance for our purposes. Therefore, additional assays such as the Thrombin Generation Assay (TGA), thrombelastometry and, at a later stage, on targeted approaches such as quantification of distinct compounds of the coagulation system, the contact phase and beyond were performed.
The analytical approaches and experiments confirming the major biochemical root cause and excluding additional factors are described in this report. These accompanied the implementation of corrective and preventive measures into the manufacturing process, finally succeeding in the production of Octagam batches with minimized procoagulant potential, which was confirmed in an in vivo thrombogenicity model. Other Octagam quality parameters are not negatively affected by the implemented measures.
Recent publications discussed the presence of FXIa as the potential root cause of the observed TEEs, while Kallikrein (-like) activities in particular were found in batches of several intravenous immunoglobulin (IVIG) concentrates as a major proteolytical impurity (6,7).

Results


Experimental and analytical results
Our experimental and analytical approaches proved the presence of FXIa as the biochemical root cause in the TEE associated Octagam batches. This was confirmed not only by established assays but also by tailored highly specific settings. Analyses using different chromogenic or fluorogenic substrates, combined with plasmatic, corn, bean and synthetic inhibitors suggested FXIa as the procoagulant principle (not shown), and essentially revealed results as reported by another working group recently (7). Due to (more or less) limited specificities of these tools, immune-depletion experiments with immobilized antibodies to FXI and assays such as combined immune-adsorption and subsequent activity measurements added evidence to this conclusion.
Immune-adsorption of FXI and FXIa
Repeated contact of the procoagulant activity containing Octagam samples with a FXI-antibody, showed a significant reduction of FXIa activities per cycle, finally resulting in complete (below detection limit) removal of FXIa activity. This was confirmed by parallel reduction of the peak thrombin concentration (PTC) in TGA. A representative experiment is shown in Illustration1.
Adsorption of the procoagulant principle and identification of FXIa
Several commercially available adsorbents such as ion-exchange and affinity chromatography resins were investigated to remove the procoagulant principle of distinct Octagam samples. Therefore, the starting material, the column flow-through fractions and the resin eluates were investigated in TGA. If no procoagulant activity was detected in the flow-through fractions, resin eluates were further investigated. SDS-PAGE and Western blotting results using a labeled anti-FXI antibody preparation and substrate exposure were used to visualize the FXI protein bands. Illustration2 shows three prominent bands. Because the PAGE was run under reducing conditions both, the FXI zymogen (upper band) and the activated FXI heavy- and light-chains are visible. All three bands were investigated by MALDI-TOF analyses and confirmed the mentioned FXI(a) identity.
Exclusion of other procoagulant factors
Analyses using a number of chromogenic and fluorogenic substrates, combined with available plasmatic, corn, bean as well as synthetic inhibitors confirmed FXIa as the major biochemical cause for the increased procoagulant in vitro potential. Most importantly, this activity could be inhibited by incubation with a surplus of a monoclonal antibody preparation against FXI, although not specific for FXIa. Furthermore, using deficient plasmas in TGA and NATEM settings exclusively revealed activity when using a FXI deficient plasma, but not in plasmas deficient in FII, FVII, FIX or FX (not shown). As a conclusion, contributing factors were most likely were proteases of the contact phase system, namely (Pre-)Kallikrein and/or FXII(a). Spiking of FIXa, FXa and FXIa clearly revealed a reaction in the tests as expected (Illustrationi3). FXIIa (PKA) had a minor impact on PTC, dependent on the FXIIa preparation used (not shown). Spiked rKallikrein activities caused a concentration dependent increase of PTC, but this was minor compared to the influence of FXIa. Kallikrein contents below one µg per ml were measured in concerned Octagam batches. It is interesting to note that rKallikrein (i.e. free from plasmatic cross-contaminations) revealed this effect in FXI-deficient plasma, which deserves further investigation.
The current Kallikrein assay has a limit of quantification of 0.05 µg activity equivalents per ml. After implementation of the measures into the Octagam manufacturing process, Kallikrein activities were below 0.05 µg/ml in recent validation batches. However, in some batches of other IVIG brands, Kallikrein activities were detectable, with one in particular showing significant amounts (IVIG #11, Illustration4).
Thrombin Generation Assay
The TGA employed was based on the commercially available Technothrombin® (Technoclone GmbH, Austria) kit using the RC High setting. In order to avoid a bias in the setting, we started with standard human plasma (SHP). Four parts of SHP were mixed with one part (pH adjusted) IVIG samples, which provided an optimal baseline to signal ratio (not shown). After identification of FXIa as the major root cause, FXI-deficient plasma was used, which provided a wider measurement range due to a lower baseline PTC at the comparable maximum PTC obtainable. Certain other activated factors clearly have an influence on the TGA signals as expected, thus this setting was introduced only after the identification of FXIa as the only biochemical root cause for procoagulant activity. It has to be considered that potential adverse events, in particular TEEs, with other IVIGs may deserve other assay designs than the setting described, if other root causes must be identified.
The TGA setting employed by us reveals a high sensitivity for FXIa, which reaches far below one mU FXIa/ml, as demonstrated in Illustration5. In the range from zero to one mU FXIa, the PTC increases from baseline (below 50 nM PTC) to approximately 350 nM PTC. The steepness of the PTC curve in the sub-microunit FXIa range provides a very sensitive test-system. The rationale for a cut-off level of 350 nM PTC is discussed below, considering PTCs measured in TEE-associated and non-associated Octagam batches and their correlation with Wessler test results.
Additional test results
Further information was obtained by NATEM® (TEM Innovations GmbH, Munich, Germany) measurements in SHP and FXI-deficient plasma, which characterizes clot formation and propagation properties. A very good correlation between increasing FXIa levels and the shortening of clotting times was observed as presented in Illustration6.
Additional studies excluded different cytokine and growth factor signal patterns compared to non-associated Octagam batches using the EliSpot® system (AID Diagnostika GmbH, Strassberg, Germany) as potential contributing root causes. This also holds true for microparticles/microvesicles (with tissue factor) and certainly as well for traces of other (activated) coagulation factors in the final product as well (not shown).
Wessler stasis model
This state-of-the-art in vivo model was performed to detect traces of thrombogenic compounds. It is essentially independent of the inducing principle and has been used for the investigations of a number of available products, in particular coagulation factor concentrates, but is also recommended to be performed for platelet and platelet substitute products (8). Standardization and stringent control of all performance criteria renders the model an adequate, sensitive and highly reproducible model (9). After application of Octagam batches (one gram IgG/kg bw each) and subsequent ten minutes stasis of the jugular vein, excision and ex vivo scoring (0 to 4, in steps of 0.5) was performed. Activated prothrombin complex concentrate (FEIBA®, Baxter Healthcare GmbH, Vienna, Austria) was used as a positive control, whereas a comparable volume of physiological sodium chloride solution served as negative control.
The results of Octagam batch testing (TEE associated and non-associated batches) revealed a threshold concentration for visible thrombi between two and seven mU FXIa per ml of the 5% IgG solution (40-140 mU FXIa per gram IgG), administered at a dose of one gram IgG per kilogram body weight. The interrelation with FXIa, TGA and TEE associated batches is shown in Illustration5, and is further discussed below.


Discussion


Intravenous immunoglobulin concentrates (IVIG) have been used for decades for the prophylaxis and treatment of different indications (10,11). A frequency of TEEs in less than one per 10,000 infusions/patients treated is considered an anticipated rate of occurance and can be traced back to underlying diseases or thrombotic risk factors. General IVIG features were reported potentially contributing to such impact. However, there was no externally introduced contamination described causing TEEs. Among those characteristics are the increase of plasma viscosity due to transient state of hyperproteinemia with subsequent pseudo-hyponatrienemia, arterial vasospasm, high IVIG administration doses at high infusion rates and (activated) coagulation factors (12-18). Surprisingly, in 2010, an increased number of TEEs were reported, including venous and arterial thrombotic events, which were associated with the administration of distinct Octagam 5% batches to patients,.
FXIa was identified as the major biochemical root cause for the increased procoagulant potential and excluded numerous other factors. This underlines the principle importance of FXIa as an inducing factor of thromboembolic events. The clear-cut correlation of enhanced FXIa levels with an overall elevated procoagulant potential can obviously can lead to thrombosis, probably dependent on the individual risk factors, which deserve further investigation. As early as 2000, Wolberg and colleagues suggested FXIa in different IVIG brands as a potential reason for an enhanced thrombotic risk during or after IVIG administration (19). Fourteen out of 29 batches from eight IVIG manufacturers revealed shortened coagulation times and contents higher than one milliunit FXIa per milliliter. During the following decade this report was often referenced, but FXIa was seldom communicated as a reason for enhanced procoagulant activity in IVIG concentrates (20, 21). Until recently, FXIa was regarded as an important factor in supporting wound closure or thrombus growth, respectively. The mechanism of action was explained by the propagation of the clot, when driving forces like the tissue factor, exposed by injured vessels or tissues, are essentially covered by fibrin and blood cells (22). In addition, the indirect inhibition of fibrinolysis through TAFI activation may contribute to clot persistence (23). FXIa as a causative compound for clotting or thrombotic events has been disputed until recently, including its activation by thrombin (24). However, experiences with early generation FXI concentrates for treatment of haemophilia C already assumed a direct initiation effect of FXIa in thrombosis (25). This was supported by results from experimental studies in animals, in which FXIa had been applied in order to investigate potential coagulation initiation. In fact, markers of coagulation activation were elevated (26). It has to be considered that these animals were healthy, while a FXIa effect in patients with underlying diseases and risk factors could lead to thrombosis.
Therefore, a more stringent in vivo model to detect traces of procoagulant compounds has been used for decades, namely the so-called Wessler stasis model in rabbits. The sensitivity of this model on the one hand is based on the high endogenous rabbit haemostasis potential with a higher coagulation factor level than humans (27, 28). Most importantly, the venous stasis provokes a tremendous tissue damage providing a generally massive predisposition for thrombus formation, if exposed to activated factors, such as FXIa. If well standardized and controlled, substances such as physiologic sodium chloride solutions do not reveal any clot formation in this model (9). However, concerned Octagam batches with a FXIa level of more than seven milliunits per milliliter (equivalent to 140 milliunits per gram IgG) and a corresponding in vitro PTC of more than 500 nM resulted in low to moderate thrombus formation. This concentration is lower than the FXIa and PTC levels measured in TEE associated Octagam batches, which contained equal or more than 17 mU FXIa with PTCs beyond 500 nM. Octagam samples equal to or below two milliunits FXIa per milliliter did not provoke any thrombus formation in the Wessler test. Correspondingly, the FXIa threshold concentration to induce thrombi in the Wessler test lies between two and seven milliunits FXIa per ml. In conclusion, the Wessler stasis model was confirmed to be an adequate and sensitive in vivo model to detect or to exclude an enhanced thrombogenic potential, independent of the inducing compound. These results contributed to the definition of a preliminary TGA based acceptance limit for Octagam batches of 500 nM PTC, which was finally lowered to 350 nM PTC in order to increase the safety margin with respect to a minimized procoagulant potential. This limit corresponds to a FXIa content of less than one milliunit per milliliter in a 5% IgG solution. In addition, a TGA lag time of equal or longer than 11 minutes as well as a time-to-peak period of equal or larger than 19 minutes must be met for release.
TGA had turned out to be a suitable and sensitive assay to detect the procoagulant principle. The assay was further developed and characterized in communication with US and EU regulatory authorities. The numeric PTC and other parameters deserve consideration, because they are characterized by the TGA setting employed. Technothombin® based determinations of the PTC of plasma from healthy donors revealed 597 nM (SD: 226 nM) (29). Other TGAs reported normal plasma values of 497 nM (SD: 37), 458 nM (SD: 60) and even 200-800 nM, respectively (30-32). Our recent comparison of Octaplas® with fresh frozen plasma (FFP; n=18 batches or donations each) showed PTCs of 361 nM (SD: 54) and 331 nM (SD: 74), respectively. Octaplas® (and Uniplas®) represent a solvent-detergent treated plasma products derived from a pool of on average 1,000 plasma donations of healthy donors, thus providing a representative average. PTCs ranged from 262 nM to 472 nM in Octaplas/Uniplas batches and from 195 nM to 437 nM in FFP, respectively (33). Accordingly, a cut-off value of 350 nM PTC is in agreement with the thrombin generation potential of normal plasma. A recent comparison of PTCs from healthy donors (n=20) with patients suffering from symptomatic thrombophilia (n=32) revealed mean PTCs of 475 nM and 811 nM, respectively (34). While absolute PTCs reported deserve further evaluation, the differences between a normal PTC and an inherent prothrombotic potential are striking. Certainly the individual risk factors of patients must be considered, which may result in TEEs even after application of a less pronounced procoagulant challenge.
It has to be considered that a comparison with other TGA or TGT (thrombin generation test) systems always requires the detailed description of the assay performance and reagents used, such as the tissue factor and lipid concentrations. Assay impact factors such as the use of (deficient) plasma with or without corn trypsin inhibitor are discussed, as are different substrates, signal quenching effects and comparability of absolute values (6, 35). Therefore, each assay used has to be validated individually, as we performed it for the Technothrombin® based assay. It is important to note, that during a recent workshop on the ´Risk Mitigation Strategies to Address Potential Procoagulant Activity in Immune Globulin Products`, data from several groups including regulatory authorities were presented, which appeared to have comparable abilities to identify IVIG batches with increased procoagulant potential when compared to controls, despite varying different absolute PTC values or lag times (36). Therefore, a collaborative study has been initiated to evaluate the inter-laboratory performance of TGAs and their characteristics in procoagulant activity evaluation in IVIG (37). The study includes NAPTT testing, which is discussed as a potential alternative to TGA (6).
In concerned Octagam batches, FXIa was unambiguously the major root cause for the enhanced procoagulant potential. The potential presence of other or additional properties was investigated in studies analysing a contribution of microvesicles (TF), microparticles or cytokine and growth factors. These factors could be excluded, and will be reported on in more detail in separate communications. Kallikrein was identified as a detectable protease in distinct Octagam batches, but was found to be below one microgram per milliliter (corresponding activity). In this concentration range, Kallikrein has a negligible effect in the TGA. Importantly, all assay characteristics regarding a procoagulant potential in concerned Octagam batches were mimicked by FXIa spiking (Illustration5), adding further evidence as the major biochemical cause and excluding a significant contribution by other compounds.
However, high Kallikrein activities (more than one microgram per milliliter, i.e. more than 20 microgram activity equivalents per gram IgG) can contribute to the procoagulant potential as demonstrated by Kallikrein spiking experiments (Illustration4). Therefore, the TGA does not differentiate in this setting between the inducing agent, but in principle may also be suitable to detect high Kallikrein activities. This deserves consideration with respect to potential adverse events other than TEEs and requires individual validation for other IVIGs. Kallikrein or Kallikrein-like activities in the microgram range were found in several IVIGs as reported recently (7). Furthermore, a recent report regarding a subcutaneous immunoglobulin concentrate assumed a correlation between a high procoagulant potential and an increased TEE risk (38). While the mechanism of TEE induction by s.c. application remains elusive, it demonstrates that processes of other products also deserve in-depth evaluation. The EDQM European Pharmacopoeia Commission communicated that an amendment to the Ph.Eur. IVIG was proposed, which includes the identification of potential procoagulants during processing and effective reduction steps (39). This was performed extensively for Octagam and was a prerequisite for lifting of the suspension of the marketing authorization.
The individual patient predisposition to compensate or to react to a certain procoagulant challenge is hard to evaluate. As a consequence, the FXIa levels have to be minimized in the applied product. The clear identification of the biochemical root cause of the enhanced procoagulant activity in distinct Octagam batches and the correlation with in vitro and in vivo test results as well as with TEEs facilitated a targeted and efficient evaluation of the technical root cause. Therefore, understanding of the Octagam manufacturing process steps with respect to FXIa generation and removal capacities was supported by the knowledge and detection abilities of the designed or adjusted assays. Identified technical reasons for the unexpected presence of FXIa in distinct Octagam batches were discussed recently (40). Consequently, this led to corrective actions and, most importantly, to the implementation of a routine and validated FXI adsorption step early in the process using a commercially available adsorbent, which is widely used for fractionation and purification of plasma proteins. Efficacy of FXI removal is monitored by a FXI ELISA after the adsorption step, while the minimized procoagulant activity is confirmed by TGA of the final product with a validated release assay, as described above. Consequently, the European Commission has lifted the suspension of the Octagam marketing authorization in Europe on May 2011 (41). The file is currently under review by the FDA.

Abbreviations


CHMP      Committee for Medicinal Products for Human Use
APTT       Activated Partial Thromboplastin Time
EDQM      European Directorate for the Quality of Medicines & Healthcare
ELISA      Enzyme Linked ImmunoSorbent Assay
EMA        European Medicines Agency
EU          Europe
FDA        US Food and Drug Administration
FEIBA®   Factor Eight Bypassing Activity
FXI(a)     Factor XI (activated)
IVIG        Intravenous ImmunoGlobulin
MALDI-TOF Matrix Assisted Laser Desorption Ionisation-Time Of Flight
NATEM®   Thrombelastometry without additional coagulation activation
ml           milliliter
mU          milliunit
NAPTT      Non-Activatet Partial Thromboplastin Time
nM           nano-Molar
Ph.Eur.     European Pharmacopoeia
PKA          PreKallikrein Activator
PT            Prothrombin Time
PTC          Peak Thrombin Concentration
ROTEM®   Rotational ThrombElastoMetry
s.c.          subcutaneous
SD           Standard Deviation
SDS-PAGE Sodium Dodecyl Sulphate – PolyAcrylamide Gel Electrophoresis
SHP         Standard Human Plasma
TAFI        Thrombin Activated Fibrinolysis Inhibitor
TEE          ThromboEmbolic Event
TGA         Thrombin Generation Assay
TGT         Thrombin Generation Test
US           United States of America
WHO        World Health Organization

Acknowledgements


We highly acknowledge the support by our senior scientists in Vienna, Berlin and Frankfurt.and the analytical and preparative technical assistance of our R&D Plasma staff.

In addition, many colleagues from different departments and Octapharma facilities deserve our deep acknowledgement.

We are grateful to S. Meyer for proof-reading of the manuscript.

References


1. Debes A, Bauer M, Kremer S. Tolerability and safety of the intravenous immunoglobulin Octagam: a 10-year prospective observational study. Pharmacoepidemiol Drug Safety 2007; 16: 1038-1047.
2. Robak T, Mainau C, Pyringer B, Chojnowski K, Warzocha K, Dmoszynska A, Straub J, Imbach P. Efficacy and safety of a new intravenous immunoglobulin 10 % formulation (octagam®10%) in patients with immune thrombocytopenia. Haematol 2010; 15: 351-359.
3. European Medicines Agency. European Medicines Agency recommends suspension of Octagam in all EU member states. CHMP recommendation based on risk of thromboembolic reactions. EMA/CHMP/591722/2010. 24 September 2010. http://www.ema.europa.eu/docs/en_GB/document_library/Press_release/2010/09/WC500097037.
4. FDA. U.S. Food and Drug Administration. Urgent: Voluntary market withdrawel -  September 23, 2010 Octagam [Immune Globulin Intravenous (Human)] 5% Liquid preparation. http://www.fda.gov/BiologicsBloodVaccines/SafetyAvailability/Recalls/ucm227133.htm
5. European Medicines Agency. European Medicines Agency recommends lifting of suspension of Octagam. Recommendation follows implementation of improved manufacturing process and other preventive measures. http://www.ema.europa.eu/ema/index.jsp?curl=pages/news_and_events/news/2011/04/news_detail_001242.js p&murl=menus/news_and_events/news_and_events.jsp&mid=WC0b01ac058004d5c1&jsenabled=true6. Grundmann C, Kusch M, Keitel S, Hunfeld A, Breitner-Ruddock S, Seitz R, Koenig H. Modified thrombin generation assay: application to the analysis of immunoglobulin concentrates. Webmed Central Immunotherapy 2010; 1: 1-13.
7. Etscheid M, Breitner-Ruddock S, Hunfeld A, Seitz R, Dodt J. Identification of kallikrein    and FXI as impurities in therapeutic immunoglgobulins: implications for the safety and control of intravenous blood products. Vox Sang 2011; DOI: 10.1111/j.1423-0410.2011.01502.x: 1-7.
8. FDA. U.S. Food and Drug Administration. Draft Guidance for Industry for Platelet Testing and Evaluation of Platelet Substitute Products. http://www.fda.gov/BiologicsBloodVaccines/NewsEvents/WorkshopsMeetingsConferences/ucm247285.htm
9. Putz M. Animal models – predictive value; Wessler and other models. FDA. U.S. Food and Drug Administration. Risk Mitigation Strategies to Address Potential Procoagulant Activity in Immune Globulin Products. Public Workshop; Rockville, MD, US. May 17-18, 2011.
http://www.fda.gov/BiologicsBloodVaccines/NewsEvents/WorkshopsMeetingsConferences/ucm247285.htm
10. Orange JS, Hossny EM, Weiler CR, Ballow M, Berger M, Bonilla FA, Buckley R, Chinen J, El-Gamal Y, Mazer BD, Nelson RP, Patel DD, Secord E, Sorensen RU, Wasserman RL, Cunningham-Rundles C. Use of intravenous immunoglobulin in human disease: A review of evidence by members of the Primary Immunodeficiency Committee of the American Academy of Allergy, Asthma and Immunology. J Allergy Immunol 2006; 117: S525-53.
11. Galeotti C, Maddur MS, Kazatchkine MD, Mouthon L, Kaveri SV. Intravenous immunoglobulins in autoimmune and inflammatory disorders: beyond a simple substitution. Transfus Clin Biol. 2009 May;16(2):75-9.    
12. Steinberger BA, Ford SM, Coleman T: Intravenous immunoglobulin therapy results in post-infusional hyperproteinemia, increased serum viscosity, and pseudohyponatremia. American Journal of Hematology (2003) 73: 97-100.
13. Siegel J: Safety considerations in IGIV utilization. International Immunopharmacology (2006) 6: 523-527.
14. Dalakas MC: High-dose intravenous immunoglobulin and serum viscosity: risk of precipitating thromboembolic events. Neurology 1994;44:223-226.
15. Marie I, Maurey G, Herve F, et al: Intravenous immunoglobulin-associated arterial and venous thrombosis; report of a series and review of the literature. Br J Dermatol. 2006;155:714-721.
16. Baba R, Shibata A, Tsurusawa M: Single high-dose intravenous immunoglobulin therapy for kawasaki disease increases plasma viscosity. Circ.J 2005;69:962-964.
17. Grillo JA, Gorson KC, Ropper AH, et al: Rapid infusion of intravenous immune globulin in patients with neuromuscular disorders. Neurology 2001;57:1699-1701.
18. Katz U, Shoenfeld Y: Review: intravenous immunoglobulin therapy and thromboembolic complications. Lupus 2005;14:802-808.
19. Wolberg AS, Kon RH, Monroe DM, Hoffman M: Coagulation Factor XI is a contaminant in intravenous immunoglobulin preparations. American Journal of Hematology 2000; 65: 30 34.
20. Mignogna MD, Fortuna G, Leuci S, Ruoppo E, Adamo D, Fedele S. Analysis of thromboembolic risk related to high-dose intravenous immunoglobulin treatment: a preliminary clinical study of 10 patients with autoimmune mucocutaneous blistering disease. Clin Exp Dermatol 2008; 34: 145-150.
21. Mizrahi M. The hypercoagulability of intravenous immunoglobulin. Clin Adv Hematol Oncol 2011; 9: 49-50.
22. Wielders SJH, Béguin S, Hemker C, Lindhout T. Factor XI-dependent reciprocal thrombin generation consolidates blood coagulation when tissue factor is not available. Arterioscler Thromb Vasc Biol 2004; 24: 1138-1142.
23. Vance G. Nielsen, Brad L. Steenwyk, William Q. Gurley, Contact Activation Prolongs Clot Lysis Time in Human Plasma: Role of Thrombin-activatable Fibrinolysis Inhibitor and Factor XIII.  J Heart and Lung Transplant. 2006; 25: 1247-1252.
24. Meijers LCM. Feedback controversy stops here. Blood 2009; 114: 234-235.
25. Mannucci PM, Bauer KA, Santagostino E, Faioni E, Barzegar S, Coppola R, Rosenberg RD: Activation of the coagulation cascade after infusion of a factor XI concentrate in congenitally deficient patients. Blood (1994) 84(4): 1314-1319.
26. Ten Cate H, Biemond BJ, Levi M et al. Factor XIa induced activation of the intrinsic cascade in vivo. Thromb Haemost 1996; 75: 445-449.
27. Serum-induced thrombosis. Studies of its induction, and evolution under controlled conditions in vivo. Wessler S, Reiner L, Freiman DG, Reimer SM, Lertzman M.  Circulation. 1959 Nov;20:864-74.
28. Karges HE, Funk KA, Ronneberger H. Activity of coagulation and fibrinolysis parameters in animals. Arzneimittelforschung. 1994 Jun;44(6):793-7.
29. Technothrombin®, package insert. Technoclone GmbH, Vienna, Austria.
30. Orbe J, Zudaire M, Serrano R, et al: Increased thrombin generation after acute versus chronic coronary disease as assessed by the thrombin generation test. Thromb Haemost. 2008; 99: 382-7.
31. Hemker HC, Al Dieri R, Beguin S: Thrombin generation assays: accruing clinical relevance. Curr Opin Hematol. 2004; 11:170-5.
32. Brummel-Ziedins K, Vossen CY, Rosendaal FR, et al.: The plasma hemostatic proteome: thrombin generation in healthy individuals. J Thromb Haemost. 2005; 3:1472-81.
33. Pock K, Heger A, Janisch S, Svae TE, Römisch J: Thrombin generation capacity is impaired in methylene-blue treated plasma compared to normal levels in single-donor fresh-frozen plasma, a licensed solvent/detergent-treated plasma (Octaplas) and a development product (Uniplas). Transfus Apher Sci 2007 Dec;37(3):223-31.
34. Hlusi A., Slavik L., Novak P., et al.:Thrombin Generation Test an Experience of one centre in thrombophilia Patients. J Thromb Haemost 2007; 5 Supplement 2: P-M-54.
35. Tapp HJ, Grundmann C, Kusch M, Koenig H. Calibrating thrombin generation in different samples: ess effort with a less efficient substrate. O J Ather hromb 2009; 2: 6-11.
36. FDA. U.S. Food and Drug Administration. Risk Mitigation Strategies to Address Potential Procoagulant Activity in Immune Globulin Products. http://www.fda.gov/downloads/BiologicsBloodVaccines/NewsEvents/WorkshopsMeetingsConferences/UCM25802 2.pdf
http://www.fda.gov/downloads/BiologicsBloodVaccines/NewsEvents/WorkshopsMeetingsConferences/UCM258 023.pdf
37. Gray E. Development of standards for TGT and TGT test method comparability. FDA. U.S. Food and Drug Administration Risk Mitigation Strategies to Address Potential Procoagulant Activity in Immune Globulin Products. Public Workshop. Public Workshop;Rockville,MD, US. May 17-18, 2011. http://www.fda.gov/downloads/BiologicsBloodVaccines/NewsEvents/WorkshopsMeetingsConferences/UCM25802 3.pdf
38. FDA. U.S. Food and Drug Administration Important Safety Information: Risk of Thrombotic Adverse Events with Subcutaneous or Inappropriate Intravenous Use of Vivaglobin (Immune Globulin Subcutaneous). March 11, 2011. http://www.fda.gov/BiologicsBloodVaccines/SafetyAvailability/ucm246863.htm
39. European Directorate for the Quality of Medicines & HealthCare (EDQM). European Pharmacopoeia Commission. PA/PH/Exp.6B/T(11)14Com. Human normal immunoglobulin for intravenous administration. Communication May 2011.
40. Roemisch J. Preliminary product testing – prospective or retrospective studies of fractionation intermediates and products for presence of procoagulant activity.  Manufacturers´ experience : product and intermediates testing for procoagulant activity – emphasis on robustness advantages/disadvantages of test methods and preliminary results. FDA. U.S. Food and Drug Administration. Risk Mitigation Strategies to Address Potential Procoagulant Activity in Immune Globulin Products . Public Workshop; Rockville, MD, US. May 17-18, 2011; 280-293. http://www.fda.gov/downloads/BiologicsBloodVaccines/NewsEvents/WorkshopsMeetingsConferences/UCM25802 2.pdf
41. European Commission, Commission implementing decision: Lift of suspension of the national marketing authorizations. May 30, 2011. http://ec.europa.eu/health/documents/community-register/html/ho17601.htm#EndOfPage.

Source(s) of Funding


none

Competing Interests


The author Dr.Juergen Roemisch is employee of Octapharma PPGmbH.

Disclaimer


This article has been downloaded from WebmedCentral. With our unique author driven post publication peer review, contents posted on this web portal do not undergo any prepublication peer or editorial review. It is completely the responsibility of the authors to ensure not only scientific and ethical standards of the manuscript but also its grammatical accuracy. Authors must ensure that they obtain all the necessary permissions before submitting any information that requires obtaining a consent or approval from a third party. Authors should also ensure not to submit any information which they do not have the copyright of or of which they have transferred the copyrights to a third party.
Contents on WebmedCentral are purely for biomedical researchers and scientists. They are not meant to cater to the needs of an individual patient. The web portal or any content(s) therein is neither designed to support, nor replace, the relationship that exists between a patient/site visitor and his/her physician. Your use of the WebmedCentral site and its contents is entirely at your own risk. We do not take any responsibility for any harm that you may suffer or inflict on a third person by following the contents of this website.

Reviews
0 reviews posted so far

Comments
0 comments posted so far

Please use this functionality to flag objectionable, inappropriate, inaccurate, and offensive content to WebmedCentral Team and the authors.

 

Author Comments
0 comments posted so far

 

What is article Popularity?

Article popularity is calculated by considering the scores: age of the article
Popularity = (P - 1) / (T + 2)^1.5
Where
P : points is the sum of individual scores, which includes article Views, Downloads, Reviews, Comments and their weightage

Scores   Weightage
Views Points X 1
Download Points X 2
Comment Points X 5
Review Points X 10
Points= sum(Views Points + Download Points + Comment Points + Review Points)
T : time since submission in hours.
P is subtracted by 1 to negate submitter's vote.
Age factor is (time since submission in hours plus two) to the power of 1.5.factor.

How Article Quality Works?

For each article Authors/Readers, Reviewers and WMC Editors can review/rate the articles. These ratings are used to determine Feedback Scores.

In most cases, article receive ratings in the range of 0 to 10. We calculate average of all the ratings and consider it as article quality.

Quality=Average(Authors/Readers Ratings + Reviewers Ratings + WMC Editor Ratings)